Machine Introduction
 
Product Features:

1. Total efficiency is greater than 90%
2. Suitable for continuous long-time production and steady output.  Increasing machine’s piece-rate and the quality of
 the products.
3. COMPACT DESIGN:  Installation area is only 600W*800D besides the forming machine.
    The machine is suitable to work with any tube production lines.  Replacing oscillation tube type welders is easy as
    position of forming machine will not be affected.
4. Sensitive electrical parts are safely closed inside the electrical cabinet and far away from the tube welding area. 
    This effectively increases the machine’s life and decreases need for repair.
5. The input efficiency is greater than 0.95 for any kinds of tube size and output range. 
 This greatly reduces energy cost and spending on peripheral equipments.
6. EAST MAINTENANCE AND INSPECTION.
7.Dependable safety system: protection against abnormal water flow volume
                                                  protection against abnormal water temperature

                                                  protection against over voltage
                                                  protection against over current
                                                  protection against over frequency
                                                  protection against low frequency
                                                  protection against coil touch
     
A New Breakthrough in Technology Highly-Efficient, Compact Solid State Generator:
 
  • Frequency and output
    The Generator accommodates a frequency range of 60kHz to 400 kHz at an output range of 60kw to 1000kw. In case of short time heating, output power can be increased.
  • Energy savings
    Because transistors are used instead of vacuum tubes, input power can be reduced by about 30% and cooling water can be saved by 50%.
  • Compact design
    The comprehensive solid-state and low voltage design makes the unit compact in size to reduce the required installation space to one-fourth the space required by conventional vacuum-tube oscillator models.
  • Easy maintenance and inspection
    Transistors, printed circuit boards and other components are all placed at the front for easy maintenance access. Cooling water circulation system (option) helps to solve the water problems.
  • Dependable protective circuits
    The protective circuits ensure safe inverter operation in case of touching coils, no-load operations, over-load operations and other operation errors.
  • Tripping operations:
    Door interlock.Cooling water flow. Water inlet/outlet temp..IAC trip.IDC trip
    Phase fault.LOW.F trip.HI.F trip.Tank fault(coil short).Tank cap. V trip
     
Features:

ENERGY SAVING:Due to the high efficiency of the solid state inverters, both power and required cooling water is reduced.
COMPACT DESIGN:The comprehensive semiconductor design reduces the installation space required for the inverter. The total dimension is reduced to around 1/4 of the vacuum tube type  H.F. generator. Depending on customers' requirements, can be installed away from the oscillation portion and the electric cabinet.
EASY MAINTENANCE AND INSPECTION:Using low voltage to operate, it is easy to maintain and service the machine, thus saving on repair and maintenance cost.
PROTECTION FEATURES:With the full protection against: Coil touch, no load operation, over load operation, wrong operation.
     
Meeting the Growing Demand for High Performance and Compact Design:
 
  • Frequency and output
    The Generator accommodates a frequency range of 100kw to 2000 kw. Refer to the following ratings for details.
  • Energy savings
    Transistors are activated with a load power factor of 1 to ensure high conversion efficiency for the inverter. This results in a 5% reduction in input power and a 44% reduction in the required cooling water.
  • Compact design
    The comprehensive semiconductor design reduces the installation space to 90% compared with our thyristor inverters. (See attached table).
  • Easy maintenance and inspection
    Transistors, printed circuit boards and other components are all placed at the front for easy maintenance access. Cooling water circulation system(option) helps to solve the water problems.
  • Dependable protective circuits
    The protective circuits ensure safe inverter operation in case of touching coils, no-load operations, over-load operations and other operation errors.
  • Tripping operations: Door interlock.Cooling water flow.Water inlet/outlet temp..IDC trip.VDC trip.LOW.F trip.HI.F trip
  • Limited operations: IDC limit.VL limit.Power limit
 
 